Altiplano Híbrido

Needs attention

Murcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager John Ingram

Output now

7.1 MW

Load factor

10 %

Energy today

76 MWh

Availability

97.1 %

Producing

21 / 29

Open alarms

10

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

10.4 m/s N

Irradiance

466 W/m²

Temperature

22.2 °C

Cloud cover

7 %

Conditions

Clear

Substation

Yecla SE 220 kV

Voltage

219.9 kV

Frequency

49.972 Hz

Power factor

0.978

Curtailment

7 %

Day-ahead price

73.26 €/MWh

Assets

29 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

6.6 MWh

Wind

8.6 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 4.2 MW

Producing
5%

Output

0.22 MW

Today

9.1 MWh

Wind

5.9 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
1%

Output

0.03 MW

Today

6.8 MWh

Wind

4.4 m/s

Wind turbine

WTG-04

Vestas V150-4.2 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

8.2 MWh

Wind

8.4 m/s

Wind turbine

WTG-05

Vestas V150-4.2 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

6.6 MWh

Wind

8.4 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
20%

Output

0.99 MW

Today

7.6 MWh

Wind

7.8 m/s

Tracker block

PV-01

Nextracker NX Horizon · 2.4 MWp

Producing
30%

Output

0.72 MW

Today

1.5 MWh

Availability

96.3 %

Tracker block

PV-02

Soltec SF7 · 2.4 MWp

Producing
30%

Output

0.71 MW

Today

1.3 MWh

Availability

99.2 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
34%

Output

0.81 MW

Today

1.4 MWh

Availability

93.3 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
45%

Output

1.78 MW

Today

2.6 MWh

Availability

97.5 %

Tracker block

PV-05

Soltec SF7 · 2.4 MWp

Producing
29%

Output

0.70 MW

Today

1.6 MWh

Availability

93.0 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Producing
25%

Output

1.00 MW

Today

2.1 MWh

Availability

95.5 %

Tracker block

PV-07

Soltec SF7 · 2.4 MWp

Producing
31%

Output

0.73 MW

Today

1.6 MWh

Availability

99.5 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Maintenance
0%

Output

0.00 MW

Today

3.2 MWh

Availability

95.8 %

Tracker block

PV-09

Nextracker NX Horizon · 3.2 MWp

Producing
31%

Output

0.98 MW

Today

1.3 MWh

Availability

99.7 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
24%

Output

0.97 MW

Today

2.7 MWh

Availability

94.5 %

Tracker block

PV-11

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
25%

Output

1.01 MW

Today

2.4 MWh

Availability

98.7 %

Tracker block

PV-12

Soltec SF7 · 3.2 MWp

Curtailed
14%

Output

0.46 MW

Today

1.3 MWh

Availability

98.7 %

Tracker block

PV-13

Soltec SF7 · 4.0 MWp

Fault
0%

Output

0.00 MW

Today

5.3 MWh

Availability

96.8 %

Tracker block

PV-14

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
35%

Output

1.39 MW

Today

2.5 MWh

Availability

97.3 %

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Maintenance
0%

Output

0.00 MW

Today

6.1 MWh

Availability

96.9 %

Inverter skid

INV-02

Sungrow SG3125HV-MV · 3.1 MVA

Producing
20%

Output

0.62 MW

Today

3.8 MWh

Availability

96.6 %

Inverter skid

INV-03

Huawei SUN2000-215KTL · 5.0 MVA

Producing
23%

Output

1.16 MW

Today

4.1 MWh

Availability

99.4 %

Inverter skid

INV-04

Huawei SUN2000-215KTL · 3.1 MVA

Curtailed
8%

Output

0.26 MW

Today

2.4 MWh

Availability

95.4 %

Inverter skid

INV-05

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
17%

Output

0.79 MW

Today

5.8 MWh

Availability

98.5 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
16%

Output

0.75 MW

Today

5.7 MWh

Availability

99.5 %

Inverter skid

INV-07

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
41%

Output

1.88 MW

Today

6.6 MWh

Availability

98.7 %

Battery container

BESS-01

CATL EnerOne+ · 5.0 MW

Producing
61%

Output

3.05 MW

Today

0.0 MWh

State of charge

46 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
60%

Output

2.34 MW

Today

0.0 MWh

State of charge

46 %

Alarms
Site alarms
Most recent events from this site's assets.

Pitch system hydraulic pressure low

WTG-01· 11-19 10:42
Medium

Row stowed – high wind

PV-03· 11-19 10:40
Medium

Rack isolated by BMS

BESS-01· 11-19 07:46
Low

Generator winding temperature high

WTG-05· 11-19 04:18
Low

Soiling loss above threshold

PV-13· 11-18 23:03
High

Soiling loss above threshold

PV-08· 11-18 19:43
Low

Anemometer signal lost

WTG-04· 11-18 18:22
Low

Soiling loss above threshold

PV-13· 11-18 17:59
High