Altiplano Híbrido

Needs attention

Murcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager John Ingram

Output now

6.1 MW

Load factor

8 %

Energy today

73 MWh

Availability

97.1 %

Producing

21 / 29

Open alarms

10

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

9.5 m/s N

Irradiance

447 W/m²

Temperature

21.9 °C

Cloud cover

10 %

Conditions

Clear

Substation

Yecla SE 220 kV

Voltage

220.5 kV

Frequency

50.027 Hz

Power factor

0.991

Curtailment

7 %

Day-ahead price

72.17 €/MWh

Assets

29 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

6.5 MWh

Wind

6.9 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 4.2 MW

Producing
5%

Output

0.20 MW

Today

8.8 MWh

Wind

5.8 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
1%

Output

0.03 MW

Today

6.8 MWh

Wind

4.3 m/s

Wind turbine

WTG-04

Vestas V150-4.2 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

8.1 MWh

Wind

7.6 m/s

Wind turbine

WTG-05

Vestas V150-4.2 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

6.5 MWh

Wind

7.8 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
15%

Output

0.75 MW

Today

7.4 MWh

Wind

7.3 m/s

Tracker block

PV-01

Nextracker NX Horizon · 2.4 MWp

Producing
28%

Output

0.67 MW

Today

1.4 MWh

Availability

96.3 %

Tracker block

PV-02

Soltec SF7 · 2.4 MWp

Producing
33%

Output

0.80 MW

Today

1.2 MWh

Availability

99.2 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
21%

Output

0.51 MW

Today

1.3 MWh

Availability

93.3 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
43%

Output

1.73 MW

Today

2.3 MWh

Availability

97.5 %

Tracker block

PV-05

Soltec SF7 · 2.4 MWp

Producing
23%

Output

0.54 MW

Today

1.5 MWh

Availability

93.0 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Producing
29%

Output

1.17 MW

Today

1.9 MWh

Availability

95.5 %

Tracker block

PV-07

Soltec SF7 · 2.4 MWp

Producing
36%

Output

0.87 MW

Today

1.5 MWh

Availability

99.5 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Maintenance
0%

Output

0.00 MW

Today

3.1 MWh

Availability

95.8 %

Tracker block

PV-09

Nextracker NX Horizon · 3.2 MWp

Producing
20%

Output

0.65 MW

Today

1.2 MWh

Availability

99.7 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
24%

Output

0.97 MW

Today

2.5 MWh

Availability

94.5 %

Tracker block

PV-11

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
19%

Output

0.76 MW

Today

2.2 MWh

Availability

98.7 %

Tracker block

PV-12

Soltec SF7 · 3.2 MWp

Curtailed
16%

Output

0.52 MW

Today

1.2 MWh

Availability

98.7 %

Tracker block

PV-13

Soltec SF7 · 4.0 MWp

Fault
0%

Output

0.00 MW

Today

5.2 MWh

Availability

96.8 %

Tracker block

PV-14

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
40%

Output

1.59 MW

Today

2.2 MWh

Availability

97.3 %

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Maintenance
0%

Output

0.00 MW

Today

6.0 MWh

Availability

96.9 %

Inverter skid

INV-02

Sungrow SG3125HV-MV · 3.1 MVA

Producing
19%

Output

0.59 MW

Today

3.7 MWh

Availability

96.6 %

Inverter skid

INV-03

Huawei SUN2000-215KTL · 5.0 MVA

Producing
20%

Output

0.98 MW

Today

3.9 MWh

Availability

99.4 %

Inverter skid

INV-04

Huawei SUN2000-215KTL · 3.1 MVA

Curtailed
9%

Output

0.27 MW

Today

2.4 MWh

Availability

95.4 %

Inverter skid

INV-05

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
18%

Output

0.82 MW

Today

5.6 MWh

Availability

98.5 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
21%

Output

0.96 MW

Today

5.6 MWh

Availability

99.5 %

Inverter skid

INV-07

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
35%

Output

1.60 MW

Today

6.2 MWh

Availability

98.7 %

Battery container

BESS-01

CATL EnerOne+ · 5.0 MW

Producing
62%

Output

3.10 MW

Today

0.0 MWh

State of charge

44 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
64%

Output

2.50 MW

Today

0.0 MWh

State of charge

44 %

Alarms
Site alarms
Most recent events from this site's assets.

Pitch system hydraulic pressure low

WTG-01· 11-19 10:20
Medium

Row stowed – high wind

PV-03· 11-19 10:19
Medium

Rack isolated by BMS

BESS-01· 11-19 07:25
Low

Generator winding temperature high

WTG-05· 11-19 03:56
Low

Soiling loss above threshold

PV-13· 11-18 22:41
High

Soiling loss above threshold

PV-08· 11-18 19:21
Low

Anemometer signal lost

WTG-04· 11-18 18:00
Low

Soiling loss above threshold

PV-13· 11-18 17:38
High