Andévalo Híbrido

Needs attention

Andalusia · Wind + solar + storage · 73 MW installed · 9 technicians · manager Darragh Grealish

Output now

6.1 MW

Load factor

8 %

Energy today

117 MWh

Availability

96.6 %

Producing

21 / 26

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

6.1 m/s ESE

Irradiance

310 W/m²

Temperature

24.1 °C

Cloud cover

56 %

Conditions

Partly cloudy

Substation

Puebla SE 400 kV

Voltage

400.6 kV

Frequency

50.022 Hz

Power factor

0.989

Curtailment

0 %

Day-ahead price

93.10 €/MWh

Assets

26 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Producing
10%

Output

0.47 MW

Today

10.6 MWh

Wind

6.7 m/s

Wind turbine

WTG-02

Siemens Gamesa SG 5.0-145 · 5.0 MW

Standby
0%

Output

0.00 MW

Today

10.4 MWh

Wind

6.9 m/s

Wind turbine

WTG-03

Nordex N163/5.X · 6.2 MW

Producing
2%

Output

0.13 MW

Today

19.3 MWh

Wind

5.0 m/s

Wind turbine

WTG-04

Nordex N149/4.0-4.5 · 5.0 MW

Producing
1%

Output

0.06 MW

Today

13.6 MWh

Wind

4.7 m/s

Wind turbine

WTG-05

Nordex N163/5.X · 5.0 MW

Producing
50%

Output

2.49 MW

Today

13.2 MWh

Wind

9.9 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
6%

Output

0.32 MW

Today

12.3 MWh

Wind

6.2 m/s

Wind turbine

WTG-07

Vestas V162-6.2 · 5.0 MW

Fault
0%

Output

0.00 MW

Today

6.5 MWh

Wind

5.1 m/s

Wind turbine

WTG-08

Siemens Gamesa SG 5.0-145 · 6.2 MW

Producing
3%

Output

0.18 MW

Today

13.9 MWh

Wind

5.3 m/s

Tracker block

PV-01

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
22%

Output

0.88 MW

Today

2.3 MWh

Availability

94.4 %

Tracker block

PV-02

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
27%

Output

1.06 MW

Today

2.1 MWh

Availability

97.3 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
30%

Output

0.71 MW

Today

1.3 MWh

Availability

96.6 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
35%

Output

0.85 MW

Today

1.6 MWh

Availability

99.0 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
33%

Output

1.06 MW

Today

1.5 MWh

Availability

94.9 %

Tracker block

PV-06

Soltec SF7 · 3.2 MWp

Producing
24%

Output

0.77 MW

Today

1.6 MWh

Availability

97.3 %

Tracker block

PV-07

Nextracker NX Horizon · 3.2 MWp

Producing
27%

Output

0.85 MW

Today

2.0 MWh

Availability

93.9 %

Tracker block

PV-08

Nextracker NX Horizon · 2.4 MWp

Producing
27%

Output

0.65 MW

Today

1.4 MWh

Availability

97.4 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 3.2 MWp

Producing
31%

Output

0.98 MW

Today

1.9 MWh

Availability

94.7 %

Tracker block

PV-10

Nextracker NX Horizon · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

1.4 MWh

Availability

98.5 %

Inverter skid

INV-01

SMA Sunny Central 4600 UP · 3.1 MVA

Producing
14%

Output

0.43 MW

Today

3.7 MWh

Availability

97.2 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 4.6 MVA

Standby
0%

Output

0.00 MW

Today

6.6 MWh

Availability

97.0 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 3.1 MVA

Producing
26%

Output

0.82 MW

Today

5.0 MWh

Availability

96.6 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
13%

Output

0.66 MW

Today

8.7 MWh

Availability

95.4 %

Inverter skid

INV-05

Huawei SUN2000-215KTL · 4.6 MVA

Producing
27%

Output

1.24 MW

Today

7.0 MWh

Availability

98.3 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 3.1 MVA

Maintenance
0%

Output

0.00 MW

Today

4.0 MWh

Availability

98.5 %

Battery container

BESS-01

Tesla Megapack 2XL · 5.0 MW

Producing
62%

Output

3.10 MW

Today

0.0 MWh

State of charge

44 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
59%

Output

2.30 MW

Today

0.0 MWh

State of charge

44 %

Alarms
Site alarms
Most recent events from this site's assets.

Service interval exceeded

WTG-05· 11-19 06:02
Medium

Soiling loss above threshold

PV-05· 11-19 05:30
Medium

Blade ice detected

WTG-07· 11-19 02:33
High

Soiling loss above threshold

PV-08· 11-19 00:53
Low

IGBT temperature high

INV-06· 11-18 17:08
Medium

Row stowed – high wind

PV-06· 11-18 14:57
Medium