Alcázar Solar

Needs attention

Castilla-La Mancha · Solar PV · 35 MW installed · 4 technicians · manager Thomas Winter

Output now

7.9 MW

Load factor

23 %

Energy today

17 MWh

Availability

95.7 %

Producing

14 / 18

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

4.2 m/s WSW

Irradiance

246 W/m²

Temperature

24.5 °C

Cloud cover

72 %

Conditions

Overcast

Substation

Alcázar SE 220 kV

Voltage

219.7 kV

Frequency

49.979 Hz

Power factor

0.982

Curtailment

6 %

Day-ahead price

103.55 €/MWh

Assets

18 assets on site. Open one for its live 3D view.

Power flow

Tracker block

PV-01

Soltec SF7 · 2.4 MWp

Producing
21%

Output

0.50 MW

Today

1.1 MWh

Availability

94.8 %

Tracker block

PV-02

Nextracker NX Horizon · 4.0 MWp

Producing
38%

Output

1.52 MW

Today

1.9 MWh

Availability

95.0 %

Tracker block

PV-03

Nextracker NX Horizon · 2.4 MWp

Producing
31%

Output

0.75 MW

Today

1.0 MWh

Availability

93.8 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
21%

Output

0.51 MW

Today

1.2 MWh

Availability

98.3 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
34%

Output

1.10 MW

Today

2.1 MWh

Availability

97.3 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Standby
0%

Output

0.00 MW

Today

2.7 MWh

Availability

94.4 %

Tracker block

PV-07

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

1.1 MWh

Availability

97.3 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
21%

Output

0.50 MW

Today

1.2 MWh

Availability

93.7 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Curtailed
17%

Output

0.40 MW

Today

0.7 MWh

Availability

94.5 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
31%

Output

1.26 MW

Today

1.9 MWh

Availability

93.9 %

Tracker block

PV-11

Nextracker NX Horizon · 3.2 MWp

Producing
24%

Output

0.76 MW

Today

1.2 MWh

Availability

97.4 %

Tracker block

PV-12

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
26%

Output

0.63 MW

Today

1.2 MWh

Availability

94.0 %

Inverter skid

INV-01

Huawei SUN2000-215KTL · 3.1 MVA

Producing
33%

Output

1.02 MW

Today

2.0 MWh

Availability

95.1 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 5.0 MVA

Producing
29%

Output

1.46 MW

Today

3.0 MWh

Availability

99.1 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 4.6 MVA

Producing
38%

Output

1.73 MW

Today

2.7 MWh

Availability

98.0 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
20%

Output

1.01 MW

Today

2.8 MWh

Availability

94.9 %

Inverter skid

INV-05

Sungrow SG3125HV-MV · 5.0 MVA

Fault
0%

Output

0.00 MW

Today

6.5 MWh

Availability

94.8 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
26%

Output

1.21 MW

Today

2.4 MWh

Availability

96.1 %

Alarms
Site alarms
Most recent events from this site's assets.

Transformer oil level low

INV-05· 11-19 10:00
Medium

DC insulation resistance low

INV-05· 11-19 07:02
Medium

Row stowed – high wind

PV-10· 11-19 00:56
Low

Grid voltage out of band

INV-05· 11-19 00:45
Medium

Grid voltage out of band

INV-01· 11-18 19:56
Medium

Tracker stuck – motor current high

PV-01· 11-18 13:11
Low